Epa s radon mitigation standards require vent discharge points to be above the roofline and no less than 10 feet sideways or 2 feet above any windows or vents.
Can radon be vented through a wall.
Keeping the vent pipe indoors keeps it warmer enhancing the stack effect.
Saves this radon vac radon fan saves hundreds of dollars in extra materials and labor over a typical radon mitigation systems.
If the fan was not operating sewer gasses could fall down the radon vent and settle under the house.
If a roof penetration is impossible you can route the radon vent through the wall or rim joist and continue the riser up the outside of the building.
One of our competitor s incorrectly constructed systems.
Because this system is power vented by a continuously running fan it can be vented through a suitable location on the roof or at a location along the exterior wall system provided the exit port is 10 feet away from any window or door and 2 feet above.
One of the newest fans designed specifically for radon mitigation vents directly through the side wall similar to a dryer vent using an aspiration hood to mix and disperse the radon gas.
Can i just tap into my sewer vent pipe.
Ideally for a roof vented system the fan should be mounted in the attic space.
Ideally a radon vent especially a passive radon vent should penetrate the roof not a wall or rim joist.
Subtle side wall venting keeps the system out of sight by eliminating unsightly pvc pipe running on the homes exterior.
Called radon vact tm the proprietary system consists of a plug in fan exterior hood and installer purchased pvc pipe.
It means opening up walls and messing up painted drywall.
Because the radon vac side wall system evacuates through the basement side wall homeowners can avoid having pvc pipe run vertically through living areas or outside of their homes to the.
Because the radon vact tm side wall system evacuates through the basement side wall homeowners can avoid having pvc pipe run vertically through living areas or outside of their homes to the roof line.
It follows the same clearances as high efficiency gas fired heating appliances that also vent through side walls they are allowed to at least 4 feet directly below a window opening.
The vent pipe discharge point is under the overhang and approximately 3 feet from the window.
Undoubtedly the radon problem was aggravated by the need to dig a very deep foundation wall 14 feet below grade at one corner in order to reach solid soil below fill material.
This is a serious plumbing code violation and safety issue.
You have to cut through an already finished roof and make sure you get the vent flashed properly.
The foundation wall is concrete block effectively providing a chimney all around the addition for radon to rise into the space.
This can be a lot of work.
Using a sewer vent for your radon vent could be explosive and smelly.